Compliance of Indoor Air Contaminants within the Main Prayer Halls of Mosques in Malacca with Malaysia's Indoor Air Quality Standard

Main Article Content

Nur Baitul Izati Rasli
Mohd Rodzi Ismail
Nor Azam Ramli
Syabiha Shith
Amni Umirah Mohamad Nazir
Noor Faizah Fitri Md Yusof
Nazatul Syadia Zainordin

Abstract

This study examined the compliance of indoor air contaminants (total volatile organic compound [TVOC], ozone [O3], carbon monoxide [CO], formaldehyde [CH2O], particulate matter [PM1, PM2.5, PM5 and PM10] and carbon dioxide [CO2]) during Dhuhr/Friday and Asr prayers with the guideline limits in Malaysia's Industrial Code of Practice (ICOP). Monitoring was conducted from 12:00–5:00 p.m. in three prominent mosques in Malacca City, namely, M1 (a historic mosque; during Dhuhr at 1:07–1:18 p.m. to Asr at 4:31–4:42 p.m.), M2 (a historic mosque; during Friday at 1:38–1:48 p.m. to Asr at 4:33–4:50 p.m.) and M3 (a floating mosque on the Straits of Malacca; during Dhuhr at 1:12–1:27 p.m. to Asr at 4:33–4:50 p.m.). Results show that the mean concentrations of the nine indoor air contaminants in M1, M2 and M3 did not exceed ICOP's limits, except for the ozone concentration in M3 that exceeded the limit at 0.150 ppm. We conclude that the concentration levels of indoor air contaminants in the studied mosques are in compliance with Malaysia's ICOP and the non-compliance issue with regard to the ozone concentration in one of the mosques is due to the mosque's location in a busy coastal and marine area.

Article Details

How to Cite
Nur Baitul Izati Rasli, Mohd Rodzi Ismail, Nor Azam Ramli, Syabiha Shith, Amni Umirah Mohamad Nazir, Noor Faizah Fitri Md Yusof, and Nazatul Syadia Zainordin. 2026. “Compliance of Indoor Air Contaminants Within the Main Prayer Halls of Mosques in Malacca With Malaysia’s Indoor Air Quality Standard”. Journal of Construction in Developing Countries 24 (2): 105–121. https://doi.org/10.21315/Jcdc2019.24.2.5.
Section
Articles

References

Abdullah, F.H., Majid, N.H.A. and Othman, R. (2016). Defining issue of thermal comfort control through urban mosque façade design. Proceedings: Social and Behavioral Sciences, 234: 416–423. https://doi.org/10.1016/j.sbspro.2016.10.259.

Ahmed, A.Z., Rahman, S.A. and Shahrani, S. (2004). CO and CO2 concentrations in naturally-ventilated houses in Malaysia. Paper presented at the PLEA2004: The 21st Conference on Passive and Low Energy Architecture. Eindhoven, The Netherlands, 19–22 September.

Al-Dabbous, A.N., Khan, A.R., Al-Rashidi, M.S. and Awadi, L. (2013). Carbon dioxide and volatile organic compounds levels in mosque in hot arid climate. Indoor and Built Environment, 22(2): 456–464. https://doi.org/10.1177/1420326X12441807.

Amin, N.D.M., Akasah, Z.A. and Razzaly, W. (2015). Architectural evaluation of thermal comfort: Sick building syndrome symptoms in engineering education laboratories. Proceedia – Social and Behavioral Sciences, 204: 19–28. https://doi.org/10.1016/j.sbspro.2015.08.105.

Awang, N.R., Ramli, N.A., Shith, S., Zainordin, N.S. and Manogaran, H. (2018). Transformational characteristics of ground level ozone during high particulate events in urban areas of Malaysia. Air Quality, Atmosphere and Health, 11: 715–727. https://doi.org/10.1007/s11869-018-0578-0.

Department of Occupational Safety and Health (DOSH) (2010). Malaysia's Industrial Code of Practice on Indoor Air Quality. Putrajaya: DOSH, Ministry of Human Resources.

Elbayoumi, M., Ramli, N.A., Md Yusof, N.F.F., Yahaya, A.S., Al Madhoun, W. and UlSaufie, A.Z. (2014). Multivariate methods for indoor PM10 and PM2.5 modelling in naturally ventilated school buildings. Atmospheric Environment, 94: 11–21. https://doi.org/10.1016/j.atmosenv.2014.05.007.

Environmental Protection Agency (EPA) (2012). An Introduction to Indoor Air Quality (IAQ): Volatile Organic Compounds (VOCs). Washington DC: EPA. Available at: http://www.epa.gov/iaq/voc.html [Accessed on 5 March 2016].

Evans, K.A., Halterman, J.S., Hopke, P.K., Fagnano, M. and Rich, D.Q. (2014). Increased ultrafine particles and carbon monoxide concentrations are associated with asthma exacerbation among urban children. Environmental Research, 129: 11–19. https://doi.org/10.1016/j.envres.2013.12.001.

Fernández, L.C., Alvarez, R.F., Francisco Javier González-Barcala, F.J. and Portal, J.A.R. (2013). Indoor air contaminants and their impact on respiratory pathologies. Archivos de Bronconeumología, 49(1): 22–27. https://doi.org/10.1016/j.arbr.2012.11.004.

Ferro, A.R., Kopperud, R.J. and Hildemann, L.M. (2004). Source strengths for indoor human activities that resuspend particulate matter. Environmental Science and Technology, 38(6): 1759–1764. https://doi.org/10.1021/es0263893.

Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B. and Rüden, H. (2007). Particulate matter in the indoor air of classrooms: Exploratory results from Munich and surrounding area. Atmospheric Environment, 41(4): 854–866. https://doi.org/10.1016/j.atmosenv.2006.08.053.

Guais, A., Brand, G., Jacquot, L., Karrer, M., Dukan, S., Grévillot, G., Molina, T.J., Bonte, J., Regnier, M. and Schwartz, L. (2011). Toxicity of carbon dioxide: A review. Chemical Research in Toxicology, 24(12): 2061–2070. https://doi.org/10.1021/tx200220r.

Hameed, A.A. and Habeeballah, T. (2013). Air microbial contamination at the holy mosque, Makkah, Saudi Arabia. Current World Environment, 2(8): 179–187. https://doi.org/10.12944/CWE.8.2.03.

Jedrychowski, W.A., Perera, F.P., Spengler, J.D., Mroz, E., Stigter, L., Flak, E. and Jacek, R. (2013). Intrauterine exposure to fine particulate matter as a risk factor for increased susceptibility to acute broncho-pulmonary infections in early childhood. International Journal of Hygiene and Environmental Health, 216(4): 395–401. https://doi.org/10.1016/j.ijheh.2012.12.014.

Jo, W.J. and Sohn, J.Y. (2009). The effect of environmental and structural factors on indoor air quality of apartments in Korea. Building and Environment, 44(9): 1794–1802. https://doi.org/10.1016/j.buildenv.2008.12.003.

Jokl, M.V. (2000). Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC. Building and Environment, 35(8): 677–697. https://doi.org/10.1016/S0360-1323(99)00042-6.

Lee, S.C. and Chang, M. (2000). Indoor and outdoor air quality investigation at schools in Hong Kong. Chemosphere, 41(1–2): 109–113. https://doi.org/10.1016/S0045-6535(99)00396-3.

Lin, M., Horowitz, L.W., Cooper, O.R., Tarasick, D., Conley, S., Iraci, L.T. and Yates, E.L. (2015). Revisiting the evidence of increasing springtime ozone mixing ratios in the free troposphere over western North America. Geophysical Research Letters, 42(20): 8719–8728. https://doi.org/10.1002/2015GL065311.

Lin, Z. and Deng, S. (2003). The outdoor air ventilation rate in high-rise residences employing room air conditioners. Building and Environment, 38(12): 1389– 1399. https://doi.org/10.1016/j.buildenv.2003.07.001.

Malaysian Standard (MS) (2014). MS 2577:2014 Architecture and Asset Management of Masjid: Code of Practice. Kuala Lumpur: Department of Standards Malaysia.

McKendry, I.G. and Lundgren, J. (2000). Tropospheric layering of ozone in regions of urbanized complex and/or coastal terrain: A review. Progress in Physical Geography, 24(3): 329–354. https://doi.org/10.1191/030913300701542660.

Mumovic, D., Palmer, J., Davies, M., Orme, M., Ridley, I., Oreszczyn, T. and Pearson, C. (2009). Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England. Building and Environment, 44(7): 1466–1477. https://doi.org/10.1016/j.buildenv.2008.06.014.

Ocak, Y., K?l?çvuran, A., Eren, A.B., Sofuoglu, A. and Sofuoglu, S.C. (2012). Exposure to particulate matter in a mosque. Atmospheric Environment, 56: 169–176. https://doi.org/10.1016/j.atmosenv.2012.04.007.

Ponsoni, K. and Raddi, M.S.G. (2010). Indoor air quality related to occupancy at an air-conditioned public building. Brazilian Archives of Biology and Technology, 53(1): 99–103. https://doi.org/10.1590/S1516-89132010000100013.

Prihatmanti, R. and Bahauddin, A. (2014). Indoor air quality in adaptively reused heritage buildings at a UNESCO World Heritage Site, Penang, Malaysia. Journal of Construction in Developing Countries, 19(1): 69–91.

Ryoo, J.M., Johnson, M.S., Iraci, L.T., Yates, E.L. and Gore, W. (2017). Investigating sources of ozone over California using AJAX airborne measurements and models: Assessing the contribution from long-range transport. Atmospheric Environment, 155: 53–67. https://doi.org/10.1016/j.atmosenv.2017.02.008.

Salthammer, T., Mentese, S. and Marutzky, R. (2010). Formaldehyde in the indoor environment. Chemical Reviews, 110(4): 2536–2572. https://doi.org/10.1021/cr800399g.

Shan, X., Zhou, J., Chang, V.W.C. and Yang, E.H. (2016). Comparing mixing and displacement ventilation in tutorial rooms: Students' thermal comfort, sick building syndromes and short-term performance. Building and Environment, 102: 128–137. https://doi.org/10.1016/j.buildenv.2016.03.025.

Thatcher, T.L. and Layton, D.W. (1995). Deposition, resuspension and penetration of particles within a residence. Atmospheric Environment, 29(13): 1487–1497. https://doi.org/10.1016/1352-2310(95)00016-

R. Tong, L., Zhang, J., Xiao, H., Cai, Q., Huang, Z., Zhang, H. and Qian, F. (2017). Identification of the potential regions contributing to ozone at a coastal site of eastern China with air mass typology. Atmospheric Pollution Research, 8(6): 1044–1057. https://doi.org/10.1016/j.apr.2017.04.005.

Yahaya, N.Z., Ghazali, N.A., Ahmad, S., Mohammad Asri, M.A., Ibrahim, Z.F. and Ramli, N.A. (2017). Analysis of daytime and nighttime ground level ozone concentrations using Boosted regression tree technique. Environment Asia, 10(1): 118–129.