Impacts of Window Factors and Building Orientation on Energy Consumption in Residential Buildings of Humid Temperate Climatic Zone in Iran

Main Article Content

Kimia Soudbaksh
Mahrokh Etminan
Mohammad Hakimazari
Seyedehmamak Salavatian

Abstract

This article deals with the research into optimal passive design parameters, such as building’s envelope components and orientation that result in improving energy efficiency. Despite the ever-increasing demand for residential complexes in developing countries like Iran during recent decades, architects and engineers are deprived of the specific guidelines to design energy-saving residential units. The present article aims to monitor the influence of window and orientation variables through the case study in the microclimate region in Iran, which is determined to be a temperate and humid climate. The residential unit is simulated by Design Builder to assess the value of energy used to fulfill heating, cooling, lighting and annual energy consumption regarding controlled variables (shading devices and mechanical and natural ventilation). The window-to-wall ratio (WWR) is evaluated in the range of 15% to 85% for northern and southern external walls. Subsequently, the most conventional range of widthto-height ratio (WHR) among the regional dwellings reported from the National Road, Housing and Urban Development Research Center is investigated. Additionally, more variables like building orientation (BO) are considered in the parametric analysis as the effective parameter to design passive solar. The considered building is routed on the ground with the azimuth angles from 0° to 360° with 5° increments in a clockwise direction to create 72 building orientation intervals. The results reveal that WWR is recommended to be 15% and 65% on the northern and southern façade, respectively. Furthermore, the aspect ratio of the north-facing windows has the marginal effect on energy saving compared to south-facing windows. Although there is an optimal building orientation, most of the ideal values can be found in the narrow ranges 175° < BO < 190° and 345° < BO < 20°. Findings indicated that the reported variables played an important role in the reduction of energy consumption, particularly in housing units of residential complexes.

Article Details

How to Cite
Kimia Soudbaksh, Mahrokh Etminan, Mohammad Hakimazari, and Seyedehmamak Salavatian. 2022. “ Impacts of Window Factors and Building Orientation on Energy Consumption in Residential Buildings of Humid Temperate Climatic Zone in Iran”. Journal of Construction in Developing Countries 27 (2): 235–262. https://doi.org/10.21315/jcdc-04-21-0061.
Section
Articles

References

Abanda, F.H. and Byers, L. (2016). An investigation of the impact of building orientation on energy consumption in a domestic building using emerging BIM (Building Information Modelling). Energy, 97: 517–527. https://doi.org/10.1016/j.energy.2015.12.135

Ahmed, M.A.A.E.D. and Fikry, M.A. (2019). Impact of glass facades on internal environment of buildings in hot arid zone. Alexandria Engineering Journal, 58(3): 1063–1075. https://doi.org/10.1016/j.aej.2019.09.009

Aksoy, U.T. and Inalli, M. (2006). Impacts of some building passive design parameters on heating demand for a cold region. Building and Environment, 41(12): 1742–1754. https://doi.org/10.1016/j.buildenv.2005.07.011

Alghoul, S.K., Rijabo, H.G. and Mashena, M.E. (2017). Energy consumption in buildings: A correlation for the influence of window to wall ratio and window orientation in Tripoli, Libya. Journal of Building Engineering, 11: 82–86. https://doi.org/10.1016/j.jobe.2017.04.003

Alwetaishi, M. (2019). Impact of glazing to wall ratio in various climatic regions: A case study. Journal of King Saud University-Engineering Sciences, 31(1): 6–18. https://doi.org/10.1016/j.jksues.2017.03.001

ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) (1997). ASHRAE Handbook 1997: Fundamentals. SI Ed. Atlanta, GA: ASHRAE.

_____. (1993). 1993 ASHRAE Handbook: Fundamentals. Atlanta, GA: ASHRAE.

ASHRAE Standard 90.1. (2019). Energy Standard for Buildings Except Low-Rise Residential Buildings (ANSI Approved; IES Co-sponsored). SI Ed. Atlanta, GA: ASHRAE.

Badeche, M. and Bouchahm, Y. (2020). Design optimization criteria for windows providing low energy demand in office buildings in Algeria. Environmental and Sustainability Indicators, 6: 100024. https://doi.org/10.1016/j.indic.2020.100024

Bülow-Hübe, H. (2001). Energy-efficient window systems-effects on energy use and daylight in buildings. Available at: https://portal.research.lu.se/portal/files/6098864/4392986.pdf

Chi, F., Wang, Y., Wang, R., Li, G. and Peng, C. (2020). An investigation of optimal window-to-wall ratio based on changes in building orientations for traditional dwellings. Solar Energy, 195: 64–81. https://doi.org/10.1016/j.solener.2019.11.033

Deru, M. and Torcellini, P. (2007). Source Energy and Emission Factors for Energy Use in Buildings (Revised) (No. NREL/TP-550-38617). Golden, CO: National Renewable Energy Lab. https://doi.org/10.2172/884990

Detsi, M., Manolitsis, A., Atsonios, I., Mandilaras, I. and Founti, M. (2020). Energy savings in an office building with high WWR using glazing systems combining thermochromic and electrochromic layers. Energies, 13(11): 3020. https://doi.org/10.3390/en13113020

EIA (Energy Information Administration) (2011). The International Energy Outlook 2011. Washington DC: US EIA. Available at: https://www.eia.gov/totalenergy/data/annual/pdf/aer.pdf

Feng, G., Chi, D., Xu, X., Dou, B., Sun, Y. and Fu, Y. (2017). Study on the influence of window-wall ratio on the energy consumption of nearly zero energy buildings. Procedia Engineering, 205: 730–737. https://doi.org/10.1016/j.proeng.2017.10.003

Ganji, M.H. (2003). Iranian continental divisions. Scientific Bulletin of the National Center for Climatology, Tehran, 41.

Garcia-Hansen, V., Esteves, A. and Pattini, A. (2002). Passive solar systems for heating, daylighting and ventilation for rooms without an equator-facing facade. Renewable Energy, 26(1): 91–111. https://doi.org/10.1016/S0960-1481(01)00089-1

Gasparella, A., Pernigotto, G., Cappelletti, F., Romagnoni, P. and Baggio, P. (2011). Analysis and modelling of window and glazing systems energy performance for a well-insulated residential building. Energy and Buildings, 43(4): 1030– 1037. https://doi.org/10.1016/j.enbuild.2010.12.032

Goia, F. (2016). Search for the optimal window-to-wall ratio in office buildings in different European climates and the implications on total energy saving potential. Solar Energy, 132: 467–492. https://doi.org/10.1016/j.solener.2016.03.031

Hassouneh, K., Alshboul, A. and Al-Salaymeh, A. (2010). Influence of windows on the energy balance of apartment buildings in Amman. Energy Conversion and Management, 51(8): 1583–1591. https://doi.org/10.1016/j.enconman.2009.08.037

Iranian Fuel Conservation Company (IFCO) (2010). Builldings office website. Available at: https://www.ecasb.com/en/company/407/Iranian-fuelconservation-company-(IFCO

Jaber, S. and Ajib, S. (2011). Optimum, technical and energy efficiency design of residential building in Mediterranean region. Energy and Buildings, 43(8): 1829–1834. https://doi.org/10.1016/j.enbuild.2011.03.024

Kasmaei, M. (2003). Climate and Architecture. Isfahan: Nashr-e-Khak.

Kim, S., Zadeh, P.A., Staub-French, S., Froese, T. and Cavka, B.T. (2016). Assessment of the impact of window size, position and orientation on building energy load using BIM. Procedia Engineering, 145: 1424–1431. https://doi.org/10.1016/j.proeng.2016.04.179

Kirimtat, A., Koyunbaba, B.K., Chatzikonstantinou, I. and Sariyildiz, S. (2016). Review of simulation modeling for shading devices in buildings. Renewable and Sustainable Energy Reviews, 53: 23–49. https://doi.org/10.1016/j.rser.2015.08.020

Koppen, W. (1936). Das geographische system der klimat. Handbuch der Klimatologie, 46.

Lai, D., Jia, S., Qi, Y. and Liu, J. (2018). Window-opening behavior in Chinese residential buildings across different climate zones. Building and Environment, 142: 234– 243. https://doi.org/10.1016/j.buildenv.2018.06.030

Lee, J.W., Jung, H.J., Park, J.Y., Lee, J.B. and Yoon, Y. (2013). Optimization of building window system in Asian regions by analyzing solar heat gain and daylighting elements. Renewable Energy, 50: 522–531. https://doi.org/10.1016/j.renene.2012.07.029

Li, N., Li, J., Fan, R. and Jia, H. (2015). Probability of occupant operation of windows during transition seasons in office buildings. Renewable Energy, 73: 84–91. https://doi.org/10.1016/j.renene.2014.05.065

Mahmoodi, M.M. (2012). The Housing Development Incompatible with Sustainable Development. Tehran: Tehran university.

Manigandan, S., Gunasekar, P., Devipriya, J. and Saravanan, W.S.R. (2016). Reduction of greenhouse gases by the effect of window position and its size in isolated building. Journal of Chemical and Pharmaceuticals Sciences.

Marino, C., Nucara, A. and Pietrafesa, M. (2017). Does window-to-wall ratio have a significant effect on the energy consumption of buildings? A parametric analysis in Italian climate conditions. Journal of Building Engineering, 13: 169– 183. https://doi.org/10.1016/j.jobe.2017.08.001

Mehrotra, M. (2005). Solar control devices: Balance between thermal performance and daylight. In Proceedings of the International Conference on Passive and Low Energy Cooling for the Built Environment, Santorini, Greece. Santorini: PALENC 2005, 19–21.

Morrissey, J., Moore, T. and Horne, R.E. (2011). Affordable passive solar design in a temperate climate: An experiment in residential building orientation. Renewable Energy, 36(2): 568–577. https://doi.org/10.1016/j.renene.2010.08.013

Muneer, T., Abodahad, N. and Kubie, J. (2000). Windows in Buildings: Thermal, Acoustic, Visual and Solar Performance. Oxford, UK: Architectural Press.

Pal, S., Roy, B. and Neogi, S. (2009). Heat transfer modelling on windows and glazing under the exposure of solar radiation. Energy and Buildings, 41(6): 654–661. https://doi.org/10.1016/j.enbuild.2009.01.003

Persson, M.L., Roos, A. and Wall, M. (2006). Influence of window size on the energy balance of low energy houses. Energy and Buildings, 38(3): 181–188. https://doi.org/10.1016/j.enbuild.2005.05.006

Pourvahidi, P. and Ozdeniz, M.B. (2013). Bioclimatic analysis of Iranian climate for energy conservation in architecture. Scientific Research and Essays, 8(1): 6–16. https://doi.org/10.5897/SRE11.518

Qasemzadeh, M. (2012). Dimensional Criteria and Design Considerations of Urban Residential Unit Spaces. Tehran: Road, Housing and Urban Development Research Center.

Rahmani, O., Rezania, S., Pour, A.B., Aminpour, S.M., Soltani, M., Ghaderpour, Y. and Oryani, B. (2020). An overview of household energy consumption and carbon dioxide emissions in Iran. Processes, 8(8): 994. https://doi.org/10.3390/pr8080994

Raji, B., Tenpierik, M.J. and Van Den Dobbelsteen, A. (2016). An assessment of energysaving solutions for the envelope design of high-rise buildings in temperate climates: A case study in the Netherlands. Energy and Buildings, 124: 210–221. https://doi.org/10.1016/j.enbuild.2015.10.049

Rana, J., Hasan, R., Sobuz, H.R. and Tam, V.W. (2022). Impact assessment of window to wall ratio on energy consumption of an office building of subtropical monsoon climatic country Bangladesh. International Journal of Construction Management, 22(13): 2528–2553. https://doi.org/10.1080/15623599.2020.1808561

Sabziparvar, A.A. (2007). General formula for estimation of monthly mean global solar radiation in different climates on the south and north coasts of Iran.International Journal of Photoenergy, 094786. https://doi.org/10.1155/2007/94786

Saifelnasr, S.S. (2016). A design chart to determine the dimensions of a horizontal shading device over an equator-facing window as a function of the latitude and the shading height. Procedia – Social and Behavioral Sciences, 216: 724– 735. https://doi.org/10.1016/j.sbspro.2015.12.069

Statistical Center of Iran (SCI) (2018). Selected Findings of the 2016 National Population and Housing Census. Tehran: SCI. Available at: https://www.amar.org.ir/english/Population-and-Housing-Censuses

Susorova, I., Tabibzadeh, M., Rahman, A., Clack, H.L. and Elnimeiri, M. (2013). The effect of geometry factors on fenestration energy performance and energy savings in office buildings. Energy and Buildings, 57: 6–13. https://doi.org/10.1016/j.enbuild.2012.10.035

Tokbolat, S., Tokpatayeva, R. and al-Zubaidy, S.N. (2013). The effects of orientation on energy consumption in buildings in Kazakhstan. Journal of Solar Energy Engineering, 135(4): 040902. https://doi.org/10.1115/1.4025427

Xu, X., Yuan, D., Sha, H., Ji, Y. and Xu, P. (2012). Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment. Expanded Polystyrene, 30: 1–42.

You, W. and Ding, W. (2015). Building façade opening evaluation using integrated energy simulation and automatic generation programs. Architectural Science Review, 58(3): 205–220. https://doi.org/10.1080/00038628.2015.1018118

Yu, J., Yang, C. and Tian, L. (2008). Low-energy envelope design of residential building in hot summer and cold winter zone in China. Energy and Buildings, 40(8): 1536–1546. https://doi.org/10.1016/j.enbuild.2008.02.020