Maintenance Feedback Mechanisms and Limiting Factors of Post-Occupancy Evaluation in Student Residents of Higher Education Institutions in Nigeria
Main Article Content
Abstract
A hostel facility’s effective functioning and performance contribute significantly to advancing knowledge and technologies for a sustainable future. Therefore, post-occupancy evaluation (POE) offers the basis for promoting construction projects’ future design and construction quality. The present study thereby examines the maintenance feedback mechanisms and limiting factors of POE to address future occupants’ satisfaction in selected hostels in Nigerian universities. A quantitative research design method was adopted where 340 questionnaire instruments were administered to the student occupants and facilities managers. The data obtained were subjected to descriptive statistics using a mean score, relative importance index and ranking. The research findings revealed that the maintenance feedback mechanisms utilised both by the student and facilities manager respondents have direct communication channels with the relevant stakeholders. The limiting factors of POE analysed showed that non-availability of information on building facilities, the persistence of maintenance challenges in building, lack of commitment from school management and insignificant improvement on the maintenance challenges were severe factors to be tackled in the studied hostels. Therefore, it is recommended that Nigerian universities’ regulating bodies conduct a building performance evaluation of existing hostel facilities in Nigerian universities and update the procedures guide and physical development manual for Nigeria’s university system.
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
References
Adewunmi, Y., Omirin, M., Famuyiwa, F. and Farinloye, O. (2011). Post-occupancy evaluation of postgraduate hostel facilities. Facilities, 29(3/4):149–168. https://doi.org/10.1108/02632771111109270
Agyekum, K., Ayarkwa, J. and Amoah, P. (2016). Post occupancy evaluation of postgraduate students’ hostel facilities and services. Journal of Building Performance, 7(1): 97–104.
Akanmu, W. P., Nunayon, S. S. and Eboson, U. C. (2020). Indoor environmental quality (IEQ) assessment of Nigerian university libraries: A pilot study. Energy and Built Environment, 2(3): 302–314. https://doi.org/10.1016/j.enbenv.2020.07.004
Alborz, N and Berardi, U. (2015). A post occupancy evaluation framework for LEED certified US higher education residence halls. Procedia Engineering, 118: 19– 27. https://doi.org/10.1016/j.proeng.2015.08.399
Amole, D. (2009). Residential satisfaction and levels of environment in students’ residences. Environment and Behavior, 41(6): 866–879. https://doi.org/10.1177/0013916508322175
Bashir, S., Sarki, I.H. and Samidi, J. (2012). Students’ perception on the service quality of Malaysian universities’ hostel accommodation. International Journal of Business and Social Science, 3(15): 213–222.
Bonde, M. and Ramirez, J. (2015). A post-occupancy evaluation of a green rated and conventional on-campus residence hall. International Journal of Sustainable Built Environment, 4(2): 400–408. https://doi.org/10.1016/j.ijsbe.2015.07.004
Bordass, B. and Leaman, A. (2005). Making feedback and post-occupancy evaluation routine 3: Case studies of the use of techniques in the feedback portfolio. Building Research and Information, 33(4): 361–375. https://doi.org/10.1080/09613210500162032
Bordass, W., Leaman, A. and Eley, J. (2006). A guide to feedback and postoccupancy evaluation. The Usable Buildings Trust, 1–17.
Busch-Geertsema, V. and Sahlin, I. (2007). The role of hostels and temporary accommodation. European Journal of Homelessness, 1: 67–93.
Cambridge Advanced Learners English Dictionary (2008). Feedback. Berlin: PONSWorterbucher, Klett Ernst Verlag GmbH.
Dahlan, N. D., Jones, P. J., Alexander, D. K., Salleh, E. and Alias, J. (2009). Evidence base prioritisation of indoor comfort perceptions in Malaysian typical multistorey hostels. Building and Environment, 44(10): 2158–2165. https://doi.org/10.1016/j.buildenv.2009.03.010
Dhaka, S., Mathur, J., Wagner, A., Agarwal, G. D. and Garg, V. (2013). Evaluation of thermal environmental conditions and thermal perception at naturally ventilated hostels of undergraduate students in composite climate. Building and Environment, 66: 42–53. https://doi.org/10.1016/j.buildenv.2013.04.015
Hadjri, K. and Crozier, C. (2009). Post?occupancy evaluation: purpose, benefits and barriers. Facilities, 27(1/2): 21–33. https://doi.org/10.1108/02632770910923063
Ibem, E.O., Opoko, A.P., Adeboye, A.B. and Amole, D. (2013). Performance evaluation of residential buildings in public housing estates in Ogun State, Nigeria: Users’ satisfaction perspective. Frontiers of Architectural Research, 2(2): 178–190. https://doi.org/10.1016/j.foar.2013.02.001
Ishak, R.A., Martosenjoyo, T., Beddu, S. and Latif, S. (2020). Post occupancy evaluation in the Senate Room, Faculty of Engineering, Hasanuddin University, Gowa. Materials Science and Engineering, 875(1): 012009. https://doi.org/10.1088/1757-899X/875/1/012009
Jiboye, A.D. (2012). Post-occupancy evaluation of residential satisfaction in Lagos, Nigeria: Feedback for residential improvement. Frontiers of Architectural Research, 1(3): 236–243. https://doi.org/10.1016/j.foar.2012.08.001
Kobue, T., Oke, A. and Aigbavboa, C. (2017). Understanding the determinants of students’ choice of occupancy for creative construction. Procedia Engineering, 196: 423–428. https://doi.org/10.1016/j.proeng.2017.07.219
Krejcie, R.V. and Morgan, D.W. (1970). Determining sample size for research activities. Educational and Psychological Measurement, 30(3): 607–610.
Krishnan, A.R., Kasim, M.M. and Bakar, E.M. (2015). A short survey on the usage of choquet integral and its associated fuzzy measure in multiple attribute analysis. Procedia Computer Science, 59: 427–434. https://doi.org/10.1016/J.PROCS.2015.07.560
Lai, J.H.K. (2013). Gap theory-based analysis of user expectation and satisfaction: The case of a hostel building. Building and Environment, 69: 183–193. https://doi.org/10.1016/j.buildenv.2013.08.006
Li, P., Froese, T.M. and Brager, G. (2018). Post-occupancy evaluation: State-of-theart analysis and state-of-the-practice review. Building and Environment, 133: 187–202. https://doi.org/10.1016/j.buildenv.2018.02.024
Mustafa, F.A. (2017). Performance assessment of buildings via post-occupancy evaluation: A case study of the building of the architecture and software engineering departments in Salahaddin University-Erbil, Iraq. Frontiers of Architectural Research, 6: 412–429. https://doi.org/10.1016/j.foar.2017.06.004
Najib, N.U.M. and Sani, N.M. (2012). The effects of students’ socio-physical backgrounds onto satisfaction with student housing facilities. ProcediaSocial and Behavioral Sciences, 62: 64–74. https://doi.org/10.1016/j.sbspro.2012.09.013
Najib, N.U.M., Yusof, N.A. and Abidin, N.Z. (2011). Student residential satisfaction in research universities. Journal of Facilities Management, 9(3): 200–212. https://doi.org/10.1108/14725961111148108
Ofide, B., Jimoh, R. and Achuenu, E. (2015): Assessment of building maintenance management practices of higher education institutions in Niger State – Nigeria. Journal of Design and Built Environment, 15(2): 1–14. https://doi.org/10.22452/jdbe.vol15no2.4
Okolie, K.C. and Shakantu, W.M. (2012). Educational building performance evaluation practices and perceptions: A case of federal universities in South East Nigeria. Journal of Construction Project Management and Innovation, 2(2): 314–330.
Okuntade, T.F. (2014). Effects of faulty construction on building maintenance. International Journal of Technology Enhancements and Emerging Engineering Research, 2(3): 73–79.
Olatunji, A. A. (2013). Post-occupancy evaluation of Lagos State Polytechnic Facilities: A user-based system. Journal of Emerging Trends in Engineering and Applied Sciences, 4(2): 229–236.
Omonijo, D.O., Anyaegbunam, M.C., Ejoh, S.I. and Ogechukwu, J.A.C. (2020). Qualitative analysis of the student industrial work experience scheme (SIWES) in tertiary institutions in Ogun State, Nigeria. Journal of Educational and Social Research, 10(4): 187–187. https://doi.org/10.36941/jesr-2020-0077
Preiser, W. F. (1995). Post?occupancy evaluation: How to make buildings work better. Facilities, 13(11): 19–28. https://doi.org/10.1108/02632779510097787
Preiser, W., Gray, C., Heath, D., Fishe, E., Gendron, P., Green, S. and Johnson, J. (1978). Public Building Accessibility: A Self Evaluation Guide. Albuquerque, NM: School of Architecture and Planning, University of New Mexico.
Preiser, W., Rabinowitz, H. and White, E. (1988). Post-Occupancy Evaluation. New York: Van Nosstrand Reinhold.
RIBA (Royal Institute of British Architects) (1965). Handbook of Architectural Practice and Management. London: RIBA Publications.
Sadick, A. M., Kpamma, Z. E. and Agyefi-Mensah, S. (2020). Impact of indoor environmental quality on job satisfaction and self-reported productivity of university employees in a tropical African climate. Building and Environment, 181: 107102. https://doi.org/10.1016/j.buildenv.2020.107102
Sanni-Anibire, M. O., Hassanain, M. A. and Al-Hammad, A. M. (2016). Postoccupancy evaluation of housing facilities: Overview and summary of methods. Journal of Performance of Constructed Facilities, 30(5): 04016009. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000868
Stevenson, F. (2009). Post-occupancy evaluation and sustainability: a review. Proceedings of the Institution of Civil Engineers-Urban Design and Planning, 162(3): 123–130. https://doi.org/10.1680/udap.2009.162.3.123
Strelets, K., Perlova, E., Platonova, M., Pankova, A., Romero, M. and Al-Shabab, M. S. (2016). Post occupancy evaluation (POE) and energy conservation opportunities (ECOs) study for three facilities in SPbPU in Saint Petersburg. Procedia Engineering, 165: 1568–1578. https://doi.org/10.1016/j.proeng.2016.11.895
Tang, H., Ding, Y. and Singer, B. C. (2020). Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China. Journal of Building Engineering, 32: 101649. https://doi.org/10.1016/j.jobe.2020.101649
Zuhaib, S., Manton, R., Griffin, C., Hajdukiewicz, M., Keane, M. M. and Goggins, J. (2018). An Indoor Environmental Quality (IEQ) assessment of a partiallyretrofitted university building. Building and Environment, 139: 69–85. https://doi.org/10.1016/j.buildenv.2018.05.001